Skip to content

Classify spectral peakedness

What it does

Returns whether both PKL and AKL meet their respective thresholds, including equality.

When to use it

Use it after peakedness to select spectra with sufficient band concentration and relative peak height. Choose thresholds for the analysis rather than treating them as universal quality criteria.

Canonical ID: tools.ispeaky

Inputs

Name Meaning Type Unit Requirements
pkl Power-concentration peakedness measures. real vector or matrix % NaN allowed; Inf allowed
akl Relative-maximum peakedness measures with the same shape as PKL. real vector or matrix % NaN allowed; Inf allowed

Parameters

Name Meaning Type Unit Default Requirements
pkl_threshold Inclusive lower threshold for PKL, between zero and 100. real scalar % not applicable minimum: 0; maximum: 100
akl_threshold Inclusive lower threshold for AKL, between zero and 100. real scalar % not applicable minimum: 0; maximum: 100

Outputs

Name Meaning Type Unit
is_peaky Whether both thresholds are met at each position. boolean 1

Interpretation and limitations

Both thresholds are required percentages between zero and 100. Inputs must have identical shapes; classification preserves that shape. A NaN measure produces false only at that position. With an automatic reference, AKL from a nonzero spectrum is 100, so PKL provides the discrimination.

References

  • Spyridon Kontaxis et al. (2020). ECG-derived Respiratory Rate in Atrial Fibrillation. IEEE Transactions on Biomedical Engineering. doi:10.1109/TBME.2019.2923587

Implementations and technical resources

Python source | MATLAB source

Normative JSON | Validation cases