Detect artifacts using Hjorth descriptors¶
What it does¶
Marks sample intervals whose windowed power, mobility or frequency spread differs from adaptive median baselines. Windows containing missing samples are also excluded.
When to use it¶
Use it on a preprocessed physiological signal when deviations in local power or waveform variation identify unsuitable segments. Margins depend on signal scaling and must match the intended analysis.
Canonical ID: ppg.hjorth_artifacts
Inputs¶
| Name | Meaning | Type | Unit | Requirements |
|---|---|---|---|---|
signal |
Nonempty real signal, optionally containing NaN. | real vector | a.u. | minimum length: 1; NaN allowed; finite |
sampling_frequency |
Sampling frequency in Hz. | real scalar | Hz | greater than: 0; no NaN; finite |
window_duration |
Duration of each full analysis window in seconds. | real scalar | s | greater than: 0; no NaN; finite |
step_duration |
Advance between window starts in seconds. | real scalar | s | greater than: 0; no NaN; finite |
margins |
Three rows of absolute lower and upper margins for activity, mobility, and complexity. | real vector or matrix | mixed | minimum: 0; no NaN; finite |
Parameters¶
| Name | Meaning | Type | Unit | Default | Requirements |
|---|---|---|---|---|---|
min_segment_separation |
Merge uncovered gaps strictly shorter than this duration; zero merges overlap and contiguity only. | real scalar | s | 0 |
minimum: 0 |
median_filter_order |
Median baseline length measured in analysis windows. | integer scalar | window | 300 |
minimum: 1 |
negative |
Invert the threshold decision while always excluding NaN windows. | boolean | dimensionless | no | not specified |
Outputs¶
| Name | Meaning | Type | Unit |
|---|---|---|---|
artifact_mask |
Binary sample mask of the merged artifact intervals. | real vector | 1 |
artifact_starts |
Times of the first included samples, in seconds from signal start. | real vector | s |
artifact_ends |
Times of the last included samples, in seconds from signal start. | real vector | s |
How it works¶
The signal is centered globally and analyzed in complete windows. Each descriptor is compared with a truncated, NaN-omitting median baseline plus or minus its absolute margins. The lower activity threshold is floored to 0.0001 when nonpositive. Detected windows become sample intervals, and overlap or contiguity is always merged. A positive separation also joins uncovered gaps strictly shorter than that duration.
Interpretation and limitations¶
A zero mask value means no artifact was marked there; it does not certify signal quality, particularly in an unexamined tail or between spaced windows. The default separation is zero seconds. Interval endpoints identify included samples, and the first sample is at time zero. Negative mode inverts the threshold decision, but windows containing NaN remain excluded. Plotting, if offered by an implementation, does not alter detections.
References¶
- Bo Hjorth (1970). EEG analysis based on time domain properties. Electroencephalography and Clinical Neurophysiology. doi:10.1016/0013-4694(70)90143-4